Draft Inducer Blower 115 Volts 3-Speed Fasco # B47120 (Dayton Ref 4C754, 1TDR2)

$ 69.2

Availability: 18 in stock

Description

Fasco
Draft Inducer - 3 Speed
1360/1100/830 RPM Shaded Pole Blower
1.95 amps @ 115 Volts 60hz.
Name Plate CFM 180/144/112
Sleeve Bearings
Outlet size: 4.25" x 2 5/8" approximate
Wheel = 7 1/8" x 2 1/8"
7063-7662, 7063-5986, 7063-6207
Appalachian Stove
Dayton Equivalent = 4C754, 1TDR2
7063-5673
Heatilator 7063-6596
7063-6568 (Hutch Mfg)
7063-8057 (Martin Industries)
7063-9465 (Pacific Energy)
7063-5996 (Rockhill Metal)
7063-5957 (US Stove)
7063-6512, 7163-7576
3-Speed Wiring
Common = White
Black = High
Low = Medium
Red = Low
The most common reason for this motor to be bad out of the box or burn up is to wire it incorrectly. If you put power to 2 speeds at the same time you will burn it up.
Motor can be bench tested by hooking power to the white & black leads (high speed)
not recommended for speed control
These Fasco Electric blowers / fans are sold as complete assemblies
We do not sell any parts for these units
Note: Blowers have wire leads, no power cords, plugs or switches
Be sure to
compare the dimensions
listed to your unit to be sure it will fit.
The information on this page is all the info we have.
Note Regarding Speed Controls:
With more and more people using wood burning stoves during heating of some issues surrounding the speed controls that vary the air output from centrifugal blowers. On a single speed blower, a speed control wired in series with the hot line will allow the user to control the speed of the blower. Many speed controls will not lower voltage below 60 and will not allow the wheel to slow to 0 RPM. Also, the combination of a blower and a speed control can often result in what is called “harmonic noise” – strange vibrations and/or noises in the customer’s unit. Slightly increasing or decreasing the blower speed can sometimes eliminate this problem – but it is often not 100% removable. Care should also be used in applying solid state speed control devices, as they are often installed in the common line, or in a non-polarized plug setup. So even though the motor may not be turning because the speed control is turned too low for the motor to operate, electricity is still connected to the speed control and a potential shock hazard exists. Finally, do not use light dimmer switches as speed controls for the centrifugal blower. Controls should be approved for use with the motors found in these units.
Keep in mind that the manufactures of these blowers recommend that they not be speed controlled.
Fasco Catalog # B47120
Winans Inc
DBA: Electric Motor Warehouse, Michigan
Monday - Friday 8:30am to 4:30pm EST
If you need additional information regarding this product e-mail us and we will be glad to answer your questions.
We accept Visa, Mastercard, Discover and American Express or PayPal. No COD's!
Attention: Canada Customers
No More Customs Brokerage Fees With EMW - importing merchandise from the USA is easy and cost effective UPS will not ship to a post office box-Physical Address only. This shipping cost includes the GST/HST taxes and brokerage fees. We consolidate our shipments to reduce the custom brokerage fee at the border, saving, you the customer, money. No more "hidden" costs such as to for the customs brokerage fee. No additional fees will be collected from you at the time of delivery.